When the power requirement of your system is more than 3kVA, the PowerReactor3 is your perfect solution. No other UPS has this combination of features: scalable by a factor of more than 1000, configurable for single-phase or multi-phase operation, hot-swappable modules, and parallel redundancy operation.  
 
All these features are achieved using only one standard module: Each Power Module is 3kVA in power rating and can be programmed in the field for different phase, voltage and frequency requirements.   

Extra backup time can easily be obtained by adding Battery Modules. Battery Modules are the same physical size as Power Modules and can be inserted into any available slot in the same rack.   

Whatever your system requirements - from 3kVA to 3000kVA - there is no better UPS than the PowerReactor3.

 
Parallel Redundant 
PowerReactor3 are based on parallel redundant architecture, which is designed to continuously supply power, even if fault occurs in a module. 
Modular 
Custom-build your solution with 3kVA modules, up to 3000kVA of parallel redundant power systems.
Scalable 
The scalability of PowerKinetics' new series of PowerReactor3 protects your investment, ensuring your UPS can be easily upgraded in the future. 
Flexible 
Each PowerReactor3 Power Module is a fully-functioning UPS. Build to the exact solution you need. Upsize or downsize as your requirements change.
Hot-Swappable 
PowerReactor Power Modules can be easily replaced without turning the UPS off, providing uninterrupted protection during servicing or upgrading. 
Smart Communication 
The UPS readily communicates directly with a computer through the serial port. The software can monitor the UPS remotely via the built-in serial port.
 
 
 

Three-Phase Operation 
Each 3kVA module is either three-phase input and single-phase output or three-phase input and three-phase output.

Highly Scalable  
The system can be upgraded from 3kVA to 3000kVA in 3kVA increments. This allows for a standard module to be used for installations of various sizes in an organisation.  
Multi-Master Redundancy  
Each PowerReactor3 module has its own dedicated controller, unlike other systems that attempt to provide redundancy through the use of multiple-power modules connected to one or two central controllers.  

In the PowerReador3, the greater the number of modules in a system, the greater the redundancy of all crucial components. Since the importance of mission-critical operations generally increases with the size of an installation, this feature of increasing redundancy with increasing capacity is invaluable.  
 

Comprehensive Monitoring of Operations 
An optional LCD Module can be added to monitor the UPS operation. The PowerReactor3 can also work with optional software for remote 
monitoring of UPS operations.