UPSMAN & UPSMON

The UPS management software is a client/server-application for networks and local workstations, UPSMAN is the server module, which communicates with the UPS via RS-232 cable or via Dry-Contact cables. After UPSMAN starts as a background program, it collects data from the UPS and displays pre-defined messages for any UPS events that occurs.

UPSMON is the client module and connects to UPSMAN for UPS data to be displayed on UPSMON's graphical user interface screen. The transport of data to the UPSMON can be done via TCP/IP, IPX, Named Pipes or SNMP.

Software Features:

  • Client/server software for heterogene networks and network-wide UPS access.
  • Supports RS-232 and contact UPS protocol.
  • Single solution for most operating systems on a single CD ROM
  • Supports single-phase or three-phase UPS.
  • Integrated software SNMP agent at NetWare, MS-Windows NT and OS/2.
  • Multi-UPS control locally for UNIX
  • Supports network protocols TCP/IP, IPX & Windows NT Pipes.
  • Graphical user interface for windows copatible platforms
  • Automatic unattended local shutdown
  • Automatic unattended master/slave shutdown in heterogene networks

  • Configurable Email and pager functions for UPS events like power fail.
 
MonUPS for Windows 
  • Operating systems : Windows 95, Windows 98, Windows NT 4.0 and Windows 2000.
  • Contact type UPS support for minimal system resources usage.
  • Option to run program as a Service in Windows NT and Windows 2000.
  • Automatically detects UPS connected to the serial Corn port.
  • Monitors power failure and UPS battery status.
  • Automatically saves most open documents before system shutdown.
  • User-configurable time settings for system shutdown.
  • User-configurable UPS event notification like email, pop-up messages, audio and pager functions.

  • Performs unattended and graceful system shutdown.
 
AutoDown for Windows
  • Operating systems : Windows 95, Windows 98, Windows NT 4.0 and Windows 2000.
  • RS-232 UPS communication protocol
  • Option to run program as a Service in Windows NT and Windows 2000.
  • Automatically detects UPS connected to the serial Corn port.
  • Monitors power failure and UPS battery status.
  • Automatically saves most open documents before system shutdown.
  • User-configurable time settings for system shutdown.
  • User-configurable UPS event notification like email, pop-up messages, audio and pager functions.
  • Performs unattended and graceful system shutdown.
  • Allows UPS to switch off after system is shut down, thus extending your UPS battery life span.
 
MonUPS for Novell Netware
  • Operating systems: Netware 4.x & 5.x
  • Contact type UPS support for minimal system resources usage.
  • Runs as a Netware Loadable Module, thus providing maximum protection for your server.
  • Monitors power failure and UPS battery status.
  • Network broadcast messages upon UPS events.
  • User-configurable time settings for system shutdown.
  • Performs unattended and graceful system shutdown.
 
AutoDown for Netware
  • Operating systems: Netware 4.x & 5.x
  • RS-232 UPS communication
  • Runs as a Netware Loadable Module, thus providing maximum protection for your server.
  • Monitors power failure and UPS battery status.
  • Network broadcast messages upon UPS events.
  • User-configurable time settings for system shutdown.
  • Performs unattended and graceful system shutdown.
  • Allows UPS to switch off after system is shut down, thus extending your UPS battery life span.

 
Back to Features